    NEWS2 Blood Pressure Guidance

    Guidance for populating the NEWS2 Blood Pressure Observation.

    The NEWS2 blood pressure observation reading uses the CareConnect-BloodPressure-Observation-1.

    Only the systolic part of the blood pressure observation is used in the NEWS2 score, but systems should send both the systolic and diastolic blood pressure components.

    Guidance for Populating a NEWS2 Blood Pressure Observation

    Note that some elements are “Left uncurated as no use case in NEWS2”, and are not needed for NEWS2.

    CareConnect-BloodPressure-Observation-1 element Population Guidance
    identifier A unique identifier assigned to this observation (such as a generated Universally Unique Identifier {UUID})
    basedOn Left uncurated as no use case in NEWS2
    status Fixed to "final"
    category The code is fixed to "vital-signs"
    The system is fixed to "http://hl7.org/fhir/observation-category"
    code The code MUST contain the Magic Code as per the HL7 vital signs guidance, MUST also have a SNOMED CT equivalent Magic Code and MAY have a more refined SNOMED CT concept code

    For NEWS2 blood pressure Magic Code, code is fixed to "85354-9", system is fixed to "http://loinc.org"

    For NEWS2 blood pressure SNOMED CT Magic Code, code is fixed to "75367002", system is fixed to "http://snomed.info/sct"

    For more refined SNOMED CT codes, code is from the valueSet defined here, system is fixed to "http://snomed.info/sct"

    If a more refined SNOMED CT code is used, then the userSelected element for that code MUST be checked.
    subject A link to the Patient
    context Left uncurated as no use case in NEWS2
    effective[x] The date and time that the blood pressure was taken, using effectiveDateTime
    issued Left uncurated as no use case in NEWS2
    performer A link to the performer who carried out this observation. This must be a qualified practitioner and associated organization
    dataAbsentReason Left uncurated as no use case in NEWS2 (as only observations with values should be sent for NEWS2)
    interpretation Left uncurated as no use case in NEWS2
    comment Any additional notes or actions that the performer wishes to convey
    bodySite Left uncurated as no use case in NEWS2
    method Left uncurated as no use case in NEWS2
    device Left uncurated as no use case in NEWS2
    referenceRange Left uncurated as no use case in NEWS2
    related A link to any related observations
    component[systolic].code The code MUST contain the Magic Code as per the HL7 vital signs guidance, MUST also have a SNOMED CT equivalent Magic Code and MAY have a more refined SNOMED CT concept code

    For NEWS2 systolic blood pressure Magic Code, code is fixed to "8480-6", system is fixed to "http://loinc.org"

    For NEWS2 systolic blood pressure SNOMED CT Magic Code, code is fixed to "72313002", system is fixed to "http://snomed.info/sct"
    For more refined SNOMED CT codes, code is from the valueSet defined here, system is fixed to "http://snomed.info/sct"

    If a more refined SNOMED CT code is used, then the userSelected element for that code MUST be checked.
    component[systolic].value[x] The actual systolic blood pressure reading as a valueQuantity. The unit is fixed to "mm[Hg]" and the system fixed to UCUM "http://unitsofmeasure.org"
    component[systolic].dataAbsentReason Left uncurated as no use case in NEWS2
    component[systolic].interpretation Left uncurated as no use case in NEWS2
    component[systolic].referenceRange Left uncurated as no use case in NEWS2
    component[diastolic].code code MUST contain the Magic Code as per the HL7 vital signs guidance, MUST also have a SNOMED CT equivalent Magic Code and MAY have a more refined SNOMED CT concept code

    For NEWS2 systolic blood pressure Magic Code, code is fixed to "8462-4", system is fixed to "http://loinc.org"

    For NEWS2 systolic blood pressure SNOMED CT Magic Code, code is fixed to "1091811000000102", system is fixed to "http://snomed.info/sct"
    For more refined SNOMED CT codes, code is from the valueSet defined here, system is fixed to "http://snomed.info/sct"

    If a more refined SNOMED CT code is used, then the userSelected element for that code MUST be checked
    component[diastolic].value[x] The actual systolic blood pressure reading as a valueQuantity. The unit is fixed to "mm[Hg]" and the system fixed to UCUM "http://unitsofmeasure.org"
    component[diastolic].dataAbsentReason Left uncurated as no use case in NEWS2
    component[diastolic].interpretation Left uncurated as no use case in NEWS2
    component[diastolic].referenceRange Left uncurated as no use case in NEWS2

    More Refined SNOMED CT Codes for Blood Pressure

    «75367002|Blood pressure (observable entity)|
    MINUS («271650006|Diastolic blood pressure (observable entity)|
    OR «271649006|Systolic blood pressure (observable entity)|
    OR «928021000000108|Baseline blood pressure (observable entity)|
    OR «87541000000108|Highest brachial systolic pressure (observable entity)|
    OR «723235005|Maximum blood pressure (observable entity)|
    OR «723236006|Minimum blood pressure (observable entity)|
    OR «314453003|Average diastolic blood pressure (observable entity)|
    OR «314440001|Average systolic blood pressure (observable entity)|
    OR «251073000|Invasive diastolic arterial pressure (observable entity)|
    OR «251071003|Invasive systolic arterial pressure (observable entity)|
    OR «276781007|Left ventricular end-diastolic pressure (observable entity)|
    OR «276780008|Left ventricular systolic pressure (observable entity)|
    OR «1036571000000105|Non-invasive central diastolic blood pressure (observable entity)|
    OR «1036551000000101|Non-invasive central systolic blood pressure (observable entity)|
    OR «174255007|Non-invasive diastolic arterial pressure (observable entity)|
    OR «251070002|Non-invasive systolic arterial pressure (observable entity)|
    OR «276772001|Right ventricular systolic pressure (observable entity)|
    OR «276774000|Right ventricular end-diastolic pressure (observable entity)|
    OR «399023006|Right ventricular peak systolic pressure (observable entity)|
    OR «276773006|Right ventricular diastolic pressure (observable entity)|)

    More Refined SNOMED CT Codes for Systolic Blood Pressure

    «271649006|Systolic blood pressure (observable entity)|
    MINUS («716579001|Baseline systolic blood pressure (observable entity)|
    OR «814101000000107|Systolic blood pressure centile (observable entity)|
    OR «315612005|Target systolic blood pressure (observable entity)|)

    More Refined SNOMED CT Codes for Diastolic Blood Pressure

    «271650006|Diastolic blood pressure (observable entity)|
    MINUS («716632005|Baseline diastolic blood pressure (observable entity)|
    OR «315613000|Target diastolic blood pressure (observable entity)|
    OR «814081000000101|Diastolic blood pressure centile (observable entity)|)

    Example

    Tags: design