GP Connect API 0.5.0 release notes

GP Connect 0.5.0 released on 23 Feb 2018

Introduction

The GP Connect 0.5.0 release is a re-release of the previous Access Record HTML 1.0.0-rc.5 and GP Connect 1.0.0-alpha.5 releases using the new version number standard.

A number of changes were made when re-releasing as GP Connect 0.5.0 to:

  • provide information on the new version number standard
  • tidy the specification, including:
    • removing out of date content
    • renaming content in line with new names
    • fixing broken links

Please see below for further details.

Changes

Entire specification

  • added version number banner at header of all pages, linking to versions page containing a list of all specification versions

  • renamed Access Record REST to Access Record Structured to align with new naming for this capability pack

  • removed the content of and replaced the following capability packs with an information notice, as they are not available in this version of the specification:
  • removed the top navigation menus as these are not preserved when hosting on NHS Developer Network

  • fixed a number of broken links

  • fixed title bar styling when viewing on smaller screens

Core specification

  • added Specification versioning to explain new single version number standard

  • migrated releases notes from individual capability packs into Core specification

  • removed the out of date maturity model

Access Record HTML

  • removed placeholders for structured data mappings

  • removed placeholders for content coming in future versions

Foundations

  • removed all Foundations interactions, except the metadata interaction that are not available at this version of the specification


Core specification

These changes were previously released as GP Connect 1.0.0-alpha.5 on 17 Jul 2017:

  • updated Common API guidance
    • clarification on API versioning and FHIR server root URL formats
    • more detail of the principles of resource identity
    • removed references to superseded RFC 2616, replacing with the updated references
  • updated Personal Demographics Service
    • note regarding the use of PDS trace sequence number to enable efficient caching
  • updated Spine Security Policy implementation guide (now moved to Spine Core)
    • requirement that FHIR root server URL SHALL contain practice level identifier
    • addition of HTTP status code 599 error which can in some circumstances be returned from the Spine Security Proxy
  • updated Security guidance
    • clarification of provider responsibilities for HTTP header validation
  • updated Cross organisation audit and provenance
    • clarification of the usage of JWT token for consumers and providers
  • updated Error handling guidance
    • addition of 501 HTTP Status code to guidance
  • updated Clinical terminologies
    • clearer statement on case sensitivity of terminologies in FHIR

Access Record HTML

These changes were previously released as Access Record HTML 1.0.0-rc.5 on 16 Mar 2017:

  • Updated Access Record Landing Page
    • Removed details of structured record access as that’s now covered in a separate pack.
  • Updated Access Record Design Decisions
    • Added some design guidance on how record locking impacts servicing queries/requests.
  • Updated Access Record Known Issues
    • Removed historical known issues which have now been addressed.
  • Updated Access Record View Medications
    • Minor fix to HTML template to bring thead/tbody tag usage in line with the other templates.
    • Minor wording tweak “Max Issued” to “Max Issues” for consistency.
    • Minor wording tweak “Scheduled End Date” to “Scheduled End” for consistency.
  • Updated Access Record View Problems
    • Minor fix to HTML template to bring thead/tbody tag usage in line with the other templates.

Access Record HTML

These changes were previously released as Access Record HTML 1.0.0-rc.4 on 20 Feb 2017:

  • Updated Access Record Design Decisions
    • Wording uplifted to include GP Practice designated Confidential Items.
  • Updated Design_Principles
    • Wording uplifted to include Confidential Items Exclusion.
  • Updated Allergies
    • Wording uplifted to reflect EMIS is not providing Historical Allergies.

Access Record HTML

These changes were previously released as Access Record HTML 1.0.0-rc.3 on 06 Feb 2017:

  • Updated Access Record HTML Implementation Guide
    • Added wording around ‘In-transit’ record to this page.
    • Added additional wording for Consumer Date-Ranges to include all times from the start date to the end of the end date.
    • Default Time-Frames - Problems, removed footnote indicating that this section should not have time-frames applied; time-frames are NOT applied for Active Probs, but are applied for ‘Inactive Probs’ sub-section
  • Updated Integration Cross Organisation Audit and Provenance
    • Added wording such that in the scenario where the user has a local role as well as a national role, then the national RBAC role shall be provided
    • Added a sentence to require the Spine RBAC role to be supplied where available and in preference to a local system role
  • Updated Access Record Design Decisions
    • Improved wording to make more specific around Patient Record ‘In-transit’
    • Corrected the reference to SCR timeframes
    • Made more explicit the ‘In-transit’ record guidance
  • Updated Medications
    • Past Medications subsection to have consumer supplied date range applied
  • Updated Spine Security Policy implementation guide (now moved to Spine Core)
    • Step 6 in the Operating Principle table - Data-Sharing validation check - interim DSAR solution within SSP, strategic solution out of scope for FoT.

Access Record HTML

These changes were previously released as Access Record HTML 1.0.0-rc.2 on 06 Dec 2016:

  • The elaboration of page(s) content to reflect the validation of data-sharing agreements by the Spine Security Proxy only, and the requirement that Provider Data-Sharing configuration should not be applied or changed for GP Connect interactions
  • The application of a configurable Legal Exclusion set - currently the RGCP set on TRUD - which is being reviewed with amendments/changes expected Feb 2017
  • The indication of withheld information, either arising from Patient preferences, or the application of the exclusion set to be at line item level as well as in Section Banner, as this provides more valuable information as to when and volume of exclusions
  • Configurable Section Headings
  • Configurable Section Default Date Ranges
  • Section Content Messages for provider-specific description of how sections have been populated, or where content deviates from specification - eg Clinical/Administrative Items content; Problem ‘Significance’ values; Patient withheld data indication; see Section Pages
  • Default section date range where relevant to be ‘All’ items, where Consumer date-range not supplied
  • Section Heading Changes to: Current Repeat Medications, Problems and Issues, Allergies and Adverse Reactions
  • Current Repeat Medications section - Last Issued Column to be first column in table
  • Medication sections ‘Drug’ column heading to be ‘Medication Item’
  • Past Medications section - to include references to Discontinued Repeats, Cancelled Acutes, either as ‘Type’, or within Details column
  • Investigations Section to be out of scope for Stage 1, pending further analysis
  • Observations Section to include Investigation items
  • Observations to be excluded from Clinical Items Section
  • Medications Sections to be reviewed as part of Stage 2
  • GP Name in Patient Banner (Details) to be the ‘Usual’ GP

All content is available under the Open Government Licence v3.0, except where otherwise stated